Services catalogue
Through our services, we make available to the market all the knowledge and resources necessary to address the problems and needs raised.
Current published tariffs
The public prices of the services offered by CIEMAT are published annually in the Official State Gazette of Spain (Spanish acronym: BOE).
LinkList of services
-
LMRI-IR13-002
Calibration for surface contamination (alpha, beta, gamma) monitoring with a 2-probe monitor, detection efficiency for 3 radionuclides (14C, 36Cl, 57Co, 60Co, 90Sr+90Y, 99Tc, 129I, 137Cs, 241Am, or natural U).
According to procedure P-LMRI-C-21. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-003
Calibration for surface contamination (alpha, beta, gamma) monitoring with a 3-probe monitor, detection efficiency for 3 radionuclides (14C, 36Cl, 57Co, 60Co, 90Sr+90Y, 99Tc, 129I, 137Cs, 241Am, or natural U).
According to procedure P-LMRI-C-21. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-004
Calibration for surface contamination (alpha, beta, gamma) monitoring with a 4-probe monitor, detection efficiency for 3 radionuclides (14C, 36Cl, 57Co, 60Co, 90Sr+90Y, 99Tc, 129I, 137Cs, 241Am, or natural U).
According to procedure P-LMRI-C-21. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-005
Solid radioactive source, alpha emission reference, electrodeposited on a stainless steel disc (ø 25 mm), activity 10-200 Bq of 241Am.
According to procedures P-LMRI-C-06/08. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-006
Solid radioactive source, triple alpha emission reference, electrodeposited on a stainless steel disc (ø 25 mm), activity 20-100 Bq of 233U+239Pu+241Am.
According to procedures P-LMRI-C-06/08. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-009
Solid radioactive source, gamma emission reference, point source for detector calibration (encapsulated in 75 µm polyethylene, active area ø 3 mm approximately), activity 0.1-10 KBq, ensuring that the total activity does not exceed the exemption limit, wi
According to procedures P-LMRI-C-14/16/19/20/27. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-010
Liquid radioactive source, alpha emission reference, encapsulated in a glass container, volume 1-3 ml, activity 14-28 Bq 232U, 14-28 Bq 238Pu, 50-1000 Bq 241Am, 30-300 Bq 243Am, 40-100 Bq 239+240Pu, 35-120 Bq 226Ra, 25-50 Bq 229Th, 25-50 Bq 242Pu.
According to procedures P-LMRI-C-07/29/31/34/46. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)
-
LMRI-IR13-011
Liquid radioactive source, beta emission reference, encapsulated in a glass container, volume 2-5 ml, activity concentration 0.1-10 Bq/mg of 3H / 14C / 60Co / 63Ni / 90Sr+90Y. The total activity will not exceed the corresponding exemption value.
According to procedure P-LMRI-C-11 or C-39. Certificate is issued as a National Patterns Laboratory (R.D. 533/1996)