Services catalogue
Through our services, we make available to the market all the knowledge and resources necessary to address the problems and needs raised.
Current published tariffs
The public prices of the services offered by CIEMAT are published annually in the Official State Gazette of Spain (Spanish acronym: BOE).
LinkList of services
-
MATCH-P08
Determination of 21 elements (greater constituents and traces) -as a whole- in samples of coals and ashes by Plasma Spectrometry (ICP-OES): Al, Ba, Be, Ca, Ce, Co, Cr, Cu, Fe, La, Mg, Mn, Mo, Ni, P, Sr, Ti, V, W, Y, Zn.
Solid state sample
-
MATCH-P09
Determination of 21 elements (major constituents and traces) -set- in samples of siliceous rocks by Plasma Spectrometry (ICP-OES): Al, Ba, Be, Ca, Ce, Co, Cr, Cu, Fe, La, Mg, Mn, Mo, Ni, P, Sr, Ti, V, W, Y, Zn.
Solid state sample
-
MATCH-P11
Determination of 23 elements (greater constituents and traces) -as a whole- in biological samples by Plasma Spectrometry (ICP-OES): Al, As, Ba, Be, Ca, Ce, Co, Cr, Cu, Fe, La, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V, W, Y, Zn.
Solid state sample
-
MATCH-P12
Evaluation of the quality of nebulizers in Plasma Spectroscopy (PCI) equipment.
-
MATCH-Q01
Analysis of polychlorinated biphenyls (PCB-28, PCB-52, PCB-101, PCB-118, PCB-138, PCB-153, PCB-180) in water samples using Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Sample in liquid state
-
MATCH-Q02
Analysis of organochlorine pesticides (Hexacyclohexane, Hexachlorobenzene, Simazine, Atrazine, Tercbutylazine, Aldrin, Metachlor, Isodrin, Dieldrin, Endrin and DDT derivatives) in water samples by means of Gas Chromatography coupled to Mass Spectrometry (
Sample in liquid state
-
MATCH-Q03
Analysis of polychlorinated biphenyls (PCB-28, PCB-52, PCB-101, PCB-118, PCB-138, PCB-153, PCB-180) and organochlorine pesticides (Hexacyclohexane, Hexachlorobenzene, Simazine, Atrazine, Tercbutylazine, Aldrin, Metachlor, Isodrin, Dieldrin, Endrin and DDT
Sample in liquid state
-
MATCH-Q04
Analysis of total petroleum hydrocarbons (TPH) with separation of aliphatic and aromatic chains in water samples using Gas Chromatography and Flame Ionization Detector (CG-FID).
Sample in liquid state
-
MATCH-Q06
Determination of Levoglucosan, Galactosan and Manosan in samples of particulate matter, by Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Sample retained in filter
-
MATCH-Q07
Analysis of aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), alcohols and carboxylic acids in samples of particulate matter from atmospheric aerosol by mass spectrometry coupled gas chromatography (CG-MS).
Sample retained in filter
-
MATCH-Q08
Analysis of polar and apolar fractions (dicarboxylic acids, anhydrosugars, PAHs, quinones, up to 78 compounds) in samples of particulate matter from atmospheric aerosol by means of Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Sample retained in filter
-
MATCH-Q09
Determination of volatile organic compounds, VOCs (C5-C10), retained in Ténax/Carbotrap tubes, in air samples, by thermal desorption coupled to gas chromatography with mass spectrometry detector.
Sample retained in filter
-
MATCH-Q10
Determination of siloxanes in biogas samples (CROMOSORB 102 tube retention) using Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Sample retained in filter. Does not include sampling
-
MATCH-Q11
Determination of volatile organic compounds VOCs (C5-C10) in biogas samples (retained on activated carbon) using Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Solid state sample
-
MATCH-Q12
Analysis of total petroleum hydrocarbons (TPH) with aliphatic and aromatic chain separation in culture medium samples using Gas Chromatography and Flame Ionization Detector (CG-FID).
Sample in liquid state. Determination of groups of aromatic and aliphatic compounds in liquid samples
-
MATCH-Q15
Analysis of polychlorinated biphenyls (PCB-28, PCB-52, PCB-101, PCB-118, PCB-138, PCB-153, PCB-180) in soil and sediment samples using Gas Chromatography coupled to Mass Spectrometry (CG-MS).
Solid state sample
-
MATCH-Q16
Analysis of organochlorine pesticides (Hexacyclohexane, Hexachlorobenzene, Simazine, Atrazine, Tercbutylazine, Aldrin, Metachlor, Isodrin, Dieldrin, Endrin and DDT derivatives) in soil and sediment samples by means of Gas Chromatography coupled to Mass Sp
Solid state sample
-
MATCH-Q17
Determination of phospholipid-associated long-chain organic acids (PLFA'S) in soil samples using Gas Chromatography with Flame Ionization Detector (CG-FID).
Solid state sample
-
MATCH-Q18
Analysis of total petroleum hydrocarbons (TPH) with separation of aliphatic and aromatic chains in soil and sediment samples using Gas Chromatography and Flame Ionization Detector (CG-FID).
Solid state sample
-
MATCH-R03
Determination of carbonyl compounds (C1-C5) in air samples using cartridges impregnated with 2-Dinitrophenylhydrazine and analysis by Liquid Chromatography.
Sample on filter. Does not include sampling
Tarifas vigentes publicadas
Los precios públicos de los servicios ofertados por el CIEMAT son publicados anualmente en el Boletín Oficial del Estado (BOE). A través del siguiente enlace, podrá conocer los precios que actualmente se encuentran vigentes.
Ir al BOE
